To increase Cold air entry from front side and Exhaust Hot air at back side rack NetRack offers, enhanced cooling system for data center like Inlet Blower Module, Roof Blower Module and Back Door Blower Modules.

Inlet Blower module will be installed in front bottom side of Rack available up to 600 CFM This will push cold air in to the rack and will be associated with Front Glass Door, Air seal kit, Front Filler Panels, with back Door and Roof Enhanced cooling based on Heat Load on the Rack.

Assessing power requirements is one of the primary tasks while setting up a data centre and it can be done with various methods depending upon your particular requirements like Calibrated Vector Cooling(CVC) – this technology is ideally used for high density servers. It helps in removing heat by increasing the circuit boards ratio per server chassis with utilisation of minimum fans.

Chilled water system: this system is preferably used in mid to large sized organisations; the chilled water comes in contact with equipment to lower down the heat.

Computer room air conditioner: this technique utilises air conditioners and work exactly like the conventional ones hence making it possible to drop down the temperature to normal.

We offer enhanced cooling system for data center which is much different from any conventional cooling method, With years of experience and skills we have been developing an efficient cooling system for various organisations worldwide.

Technical Specification

Model Matrix & Dimensions
DescriptionPart No.No. of FansMountingRU SpaceAir Flow-CFM
Inlet Blower ModuleIBM-6003Bottom Side0600CFM
Enhanced Cooling

Enhanced Cooling


Roof Blower module will be installed in Top back side of racks available 400 to 1300 CFM with chimney. This will exhaust hot air from rack and will be associated with Front perforated Door, Air seal kit, Front Filler Panels, with back door enhanced cooling, based on Heat Load on the rack.

 

Model Matrix & Dimensions
DescriptionPart NoMountingRU SpaceCFM/No. of Fans
Roof Blower Module/400 CFMRBM-400Top Cover0200/2
 
Roof Blower Module/400 CFM/ Adjustable ChimneyRBM-400-ACTop Cover0200/2
 
Roof Blower Module/600 CFMRBM-600Top Cover0200/3
 
Roof Blower Module/600 CFM/ Adjustable ChimneyRBM-600-ACTop Cover0200/3
 
Roof Blower Module/1300 CFMRBM-1300Top Cover0650/2
 
Roof Blower Module/1300 CFM/ Adjustable ChimneyRBM-1300-ACTop Cover0650/2
 